VITALink® 2 Hour Fire Resistive Dual Rated CI/CIC

VITALink® 2 Hour Fire Resistive CIC/CI Unshielded

Construction:

  • Conductors: 18-12 AWG Solid Copper or 16-12 AWG Stranded Copper specially engineered to minimize embrittlement due to fire exposure
  • Insulation: Low Smoke, Zero Halogen Thermoset Fire-Roc®
  • Tape: Flame Retardant Tape
  • Cable Assembly: 2 Conductors
  • Drain Wire: Stranded Bare Copper (Shielded constructions only)
  • Shield: Copper/Polyester Tape (Shielded constructions only)
  • Jacket: Red Low Smoke, Zero Halogen Polyolefin (Sequential Footage Marker Provided Every Two Feet)

Applications:

  • Emergency Voice/Alarm Communication Smoke and Fire Alarm Systems
  • Fireman’s Telephone and Area of Refuge Communication Systems
  • Visible Notification Appliances

35777, 36337, 36341, 36338, 36340, 36342, 36339

 

Part Numbers & Specs

SpecPart NumberNo. of ConductorsAWGSolid or Stranded Copper ConductorsNominal Diameter (inches)Nominal Weight (lbs./1000 ft.)
Shielded
Spec36397218Solid.30949
Spec35785216Solid.33060
Spec36316214Solid.35964
Unshielded
Spec36337218Solid.30541
Spec35777216Solid.32152
Spec36341216Stranded.34454
Spec36338214Solid.35261
Spec36340214Stranded.36865
Spec36342212Solid .40290
Spec36339212Stranded.41392

Notes:

  • Refer to installation instructions for hardware certifications
  • Refer to R27557 Fire Resistive Cable (UL)
  • VITALink® Brand Type FPLR-CI-ST1, CMR-CI-LS, & CL3R-CI-ST1 for use in System No. FHIT.40A and FHIT7.40A
  • For use as CIC cable, installation follows FHIT.40A/FHIT7.40A and Comtran’s installation instructions
  • For use as CI cable, installation follows the NEC and local code.
  • Authorities having jurisdiction should be consulted before installation.

Compliance:

  • ANSI/UL 2196 2 hour fire rating for use in FHIT System 40A (See UL Fire Resistance Directory R27557)
  • ULC-S139/2196 Listed with hose stream test for use in FHIT7 System 40A
  • UL Type FPLR-CI-ST1, CMR-CI-ST1, and CL3R-CI-ST1
  • CSA Listed FAS 105 ST1 FT4
  • UL 1424 Listed for Power-Limited Fire Alarm Cables; 300V / 105°C
  • UL 13 Listed for Power-Limited Circuit Cables; 300V / 105°C
  • UL 444 Listed for Communication Cable; 300V / 105°C
  • NFPA 70, 72, 130, 502
  • Fire certified for power-limited system use at 72V phase-to-phase utilization voltage
  • Sunlight Resistant
  • For use in wet locations
  • NYC Electrical Advisory Board approval # 54502, April 2017
  • California State Fire Marshal Approved
  • RoHS Compliant